Example of electromagnetic shielding effectiveness test
MIL-STD-188-125-2 - HEMP Protection Standard for Ground-Based Facilities
emctest technologies performs shielding effectiveness testsEMCTEST Technologies, Via Marecchiese 273, Rimini, ITALY
Phone: +39 0541 728562 | E-Mail: info@emctest.it


italian flagenglish flag

MIL-STD-188-125-2 - HEMP PROTECTION STANDARD FOR GROUND-BASED FACILITIES

The MIL-STD-188-125-2 standard addresses protection requirements against High-Altitude Electromagnetic Pulses (HEMP) for ground-based facilities. One of the core metrics for determining the reliability and efficiency of such protection is "shielding effectiveness".

Shielding effectiveness, as referred to in this standard, measures how well a barrier (such as a metal enclosure, metallic textiles, or specially designed partitions) can attenuate or reduce the electromagnetic interference (EMI) from an external source, like a HEMP event.
It's essentially a measure of how effective a shield is in preventing unwanted electromagnetic fields from penetrating through it.

Within the MIL-STD-188-125-2 standard, specific requirements for shielding effectiveness are laid out, especially concerning points of entry (POEs) like piping or ventilation systems. These systems are often vulnerable points where electromagnetic energy can enter, hence the need for strict criteria on how they should be shielded. The standard dictates the minimum levels of attenuation (often measured in decibels, dB) that protective barriers must achieve to be considered compliant.

Discover how metallic textiles and other materials can be utilized for optimal shielding in the context of this standard. Essential reading for professionals in defense, infrastructure protection, and electromagnetic interference mitigation.

For instance, if a certain section of the standard requires an 80 dB attenuation at 1 GHz, it means that the shielding should reduce the incoming electromagnetic signal's strength by 80 dB at that specific frequency. Achieving such levels ensures that the critical infrastructure inside the protected facility remains functional and unaffected by the intense electromagnetic fields associated with a HEMP event.

So the MIL-STD-188-125-2 standard underscores the importance of shielding effectiveness in safeguarding ground-based facilities from HEMP threats. As the potential consequences of inadequate shielding can be devastating, adhering to the rigorous criteria set out in the standard is essential for defense and infrastructure protection.


Emctest Technologies is a laboratory that performs shielding effectiveness tests on site, directly to the customer, in Italy and in Europe, or at its headquarters in Rimini - Italy.

We perform shielding effectiveness tests for several sectors:

  • private
  • industrial
  • medical
  • nautical
  • aviation
  • military
  • scientifical
Typical shielding effectiveness measurement frequencies are: 10 kHz, 100 kHz, 500 kHz, 1 MHz, 10 MHz, 30 MHz, 100 MHz, 433 MHz, 700 MHz, 800 MHz, 900 MHz, 1 GHz, 1.5 GHz, 2.4 GHz, 3 GHz, 5 GHz, 5,8 GHz, 6 GHz, 10 GHz, 17 GHz, 18 GHz, 24 GHz (Industrial, Scientific, and Medical - ISM - band), 26.5 GHz, 30 GHz, 35 GHz, 40 GHz, 50 GHz, 60 GHz (Wireless communication and radar applications), 75 GHz, 77 GHz (Automotive radar systems), 94 GHz, 100 GHz, 110 GHz.

Our lab test can perform shielding effectiveness measurements up to 110 GHz.


Read more about it going back to the home page. Or if you are looking for a lab in order to test your product contact us via email or by phone simply clicking here.

shielding effectiveness test example with 2 antennas
GENERAL APPLICATION FIELDS
Textile
  • Fabrics used to protect premises against electromagnetic fields
  • Realization of card holders
  • Jackets pockets
  • Shirts
  • Bags
  • Suitcases to protect RFID cards

Construction
  • Shielding panels and sheets for the construction of shielded structures such as shelters, screened rooms, reserved rooms, medical rooms, etc.

Glasses
  • Glasses to be applied to screens for small equipment
  • Glasses for the construction of shielding windows for buildings or internal dividing walls.

Applicable solutions
  • Spray
  • Shielding paints

Other shielding solutions
  • Not mentioned above

Oversize Products
  • Oversize Products
  • Aircrafts
  • Ships
  • Freighters
  • Trucks
  • Cars
  • Military Shelter
  • Container
  • Electrical cabinets / Enclosures

Constructions
  • Entire buildings
  • Rooms
  • Reserved places
  • Government premises
  • Medical facilities
  • Shielded chambers
  • Anechoic chambers

Glass Windows
  • Shielded glasses
  • Equipment screens

Applicable solutions
  • Spray for industrial use
  • Military shielding paints

Other shielding solutions
  • Not mentioned above